The wires in the mains lead are coloured in accordance
In the interest of the
with the following code:
environment
Green and Yellow- Earth
Washing machines and dishwashers should be
Blue- Neutral
connected to the FOUL drainage system, the water will
Brown- Live
then be taken to a sewage works for treatment before
being discharged safely into a river.GREEN &YELLOW
It is essential that these appliances are not connected toE
the surface water drainage system as this water is
13A
discharged directly into a river or stream and may cause
L
N
pollution. If you require any further advice please
contact your local water authority.
BROWN
BLUE
P1041CORD CLAMP
Electrical connection
Any electrical work required to install this appliance
The wire coloured green and yellow must be connected
should be carried out by a qualified electrician or
to the terminal marked with the letter �EE or by the
competent person.earth symbol or coloured green and yellow.
The wire coloured blue must be connected to the
WARNING: THIS APPLIANCE MUST BE
terminal marked �NE or coloured black.
EARTHED.
The wire coloured brown must be connected to the
The manufacturer declines any liability should
terminal marked �LE or coloured red.
this safety measure not be observed.
Upon completion there must be no cut, or stray strands
Before switching on, make sure the electricity supplyof wire present and the cord clamp must be secure over
voltage is the same as that indicated on the applianceOsthe outer sheath.
rating plate. The rating plate is located at the top of the
rim of the open door.WARNING:
A cut off plug inserted into a 13 amp socket is
M.........od..Ser.
a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
Should the appliance power supply cable need to be
Mod. ..........
Prod. No. ...........replaced, this should be carried out by our Service
Ser. No. .........Force Centre.
P0042
The appliance is supplied with a 13amp plug fitted.Note
In the event of having to change the fuse in the plug
When the appliance is installed the power supply cable
supplied, a 13amp ASTA approved (BS1363A) fuse
must be accessible.
must be used.
Should the plug need to be replaced for any reason,
Permanent connection
proceed as described below.
In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3mm between the switch contacts and of a type
suitable for the required load in compliance with the
current electrical regulations.
The switch must not break the yellow and green earth
cable at any point.